Teknium 758114bb8d fix(cron): manual run reports delivery_failed as a failed run; docs for the distinct status
A manual cronjob(action='run') derived success from last_status == 'ok'
and read the error from last_error — so a run that now records
delivery_failed came back as success=False with error=None, an unexplained
failure. Surface last_delivery_error as the error in that case (the
#84006 direction, re-applied on the delivery_failed status), and pin the
manual-run completion summary to say 'Result: FAILED' over an undelivered
run. Document the status in the cron user guide.

Co-authored-by: webtecnica <webtecnica@gmail.com>
2026-09-02 00:52:58 -07:00
Evgenii 1a8625abee fix(cron): harden gateway fire admission and provider compatibility
- The gateway api_server fire webhook acknowledges 202 only after a
  durable claim + execution row exist (admission failure stays retryable
  as 503; a live claim answers 200 duplicate), then dispatches the
  claimed snapshot with the live runner adapters (delivery parity with
  the built-in ticker, including relay-fronted and E2EE platforms).
- Legacy single-phase providers (a documented fire_due override without
  split hooks) keep being driven through their own hook. Capability
  detection now credits claim_fire AND fire_claimed overrides, so
  Chronos is correctly classified split-aware (its re-arm lives in
  fire_claimed; the redundant fire_due passthrough override is removed).
- Multi-profile dashboards fail closed for external providers: an
  unscoped reconcile would disarm other profiles' armed one-shots in the
  shared NAS registry.
- Manual runs (cronjob run) carry the owner-bearing claimed snapshot
  through every entry point, composing with upstream's manual-run
  heartbeat (#76502) and background dispatch.

Note: current main moved the dashboard NAS webhook to a pure
forward-to-gateway design (the gateway owns execution and live
adapters), so the dashboard-side claim/tracking machinery from earlier
revisions of this PR is dropped; the durable admission contract lives in
the gateway webhook path.
2026-08-14 20:46:50 -07:00
liuhao1024 66c60f81b6 fix(cron): thread per-run prompt through cronjob(action='run') (#57331)
Salvaged from PR #57342 by @liuhao1024 (with the injection-scan half
from PR #57360 by @ghedeselmabot): cronjob(action='run', prompt=...)
silently discarded the prompt argument — per-run context never
reached the spawned cron session.

The prompt is now threaded as extra_prompt through the whole chain
(cronjob run action → _try_dispatch_background_run/_execute_job_now →
_run_claimed_job → run_one_job → run_job → _build_job_prompt) and
appended to the stored prompt under a '## Run Context' header for
that single fire only — never persisted to the job definition. It
passes the same strict _scan_cron_prompt injection scan as stored
prompts before firing, and works identically on the background and
sync fallback paths.

Test fakes across tests/cron/ updated to accept the new kwargs
(sibling-test blast radius from the signature change).

Co-authored-by: liuhao1024 <liuhao1024@users.noreply.github.com>
2026-08-06 23:14:55 -07:00
Fly 7a5fe00244 fix(cron): deliver manual runs on gateway loop 2026-08-06 23:14:55 -07:00
kshitijk4poor 0cd26ce9a5 refactor(cron): log the heartbeat ceiling stop + test it
- logger.warning when the 6h ceiling stops the heartbeat (matches the
  delegate_task stale-stop precedent) so the eventual watchdog reap is
  explainable from logs instead of silent
- new mutation-checked test: past the ceiling the heartbeat stops while
  the job still completes
- clearer assertion messages (surface res on failure)
2026-08-02 14:04:52 +05:30
kshitijk4poor 8fd1a68106 refactor(cron): harden the run heartbeat (review follow-ups)
- heartbeat loop continues past a raising activity callback instead of
  silently stopping (matches delegate_task / touch_activity_if_due
  swallow-and-continue semantics) — one transient error must not drop
  watchdog protection for the rest of a long job
- hard 6h elapsed ceiling so a wedged job under HERMES_CRON_TIMEOUT=0
  (unlimited child watchdog) cannot mask the gateway watchdog forever
- public get_activity_callback() accessor in tools/environments/base.py
  instead of importing the private _get_activity_callback cross-module
- tests: deterministic heartbeat test (event-gated, no timing sleep),
  no-callback test now asserts the thread is truly never created, new
  exception-survival guard; dead started event removed
- fix comment: delegate_task heartbeat cadence is 30s, not 10s
2026-08-02 14:04:52 +05:30
webtecnica 2314abcbb0 fix(cron): run job without blocking the calling turn (#76502) 2026-08-02 14:04:52 +05:30
Teknium 39975613b1 test: prune wave 2 + speed fixes — 28,106 → 19,757 test functions, suite wall 315s → 294s
Second, deeper pass over tools/gateway/hermes_cli plus first pass over
the trees wave 1 missed (acp, acp_adapter, skills, computer_use, docker,
dashboard, conformance, monitoring, secret_sources, hermes_state,
providers). Same rubric as wave 1 (AGENTS.md test policy); security,
alternation/caching invariants, issue-number regressions, and E2E kept.

Real test-quality fixes found and rooted out along the way:
- tests/tools/test_command_guards.py made real auxiliary-LLM HTTPS calls
  (DEFAULT_CONFIG smart-approval leaked in) — pinned approval
  mode=manual via autouse fixture: 17.4s → 0.4s.
- test_model_switch_custom_providers.py / test_user_providers_model_switch.py
  silently probed live provider catalogs (~2s/test) — stubbed
  cached_provider_model_ids/provider_model_ids/fetch_api_models.
- test_telegram_noise_filter.py: 15-platform copy-paste matrix over
  shared gateway.run logic → 3 representative platforms (55s → 3.9s).
- test_gateway_shutdown.py: stop()'s 5s interrupt-deadline loop spun on
  MagicMock agents — interrupt.side_effect now clears _running_agents
  (22s → 1.0s).
- test_gateway_inactivity_timeout.py poll-harness timings shrunk 3-5x
  (24s → 1.1s); test_mcp_stability.py backoff/SIGTERM-grace sleeps
  patched (15.4s → 2.5s); test_async_delegation.py negative-drain wait
  5s → 0.5s.
- test_telegram_init_deadline.py: loop-block margin restored to 1.0s
  with rationale comment — the watchdog-dump assertion needs the loop
  blocked well past deadline+grace under parallel load (flaked once in
  the 40-worker verification run at a 0.2s margin).

Verification: full hermetic suite via scripts/run_tests.sh —
2,438 files, 21,718 tests passed, 0 failed, 293.9s wall.
Suite totals vs original baseline: 46,820 → 19,757 test functions
(−57.8%), wall 583.5s → 293.9s (−50%), subprocess CPU 13,564s → 11,623s.
2026-07-29 13:39:40 -07:00
Ben Barclay ef6ce56cad fix(cron): reconcile external provider after a claimed direct run (#70479)
A direct run (cronjob action='run' / webhook-triggered manual fire) takes
the job's fire_claim and advances next_run_at. When it races the external
provider's scheduled fire for the same occurrence, Chronos loses the claim
and — by design — does not re-arm (the winner owns the re-arm). But the
direct-run winner never notified the provider, so the NAS one-shot for the
consumed occurrence was left stale forever and the recurring job silently
stopped firing.

Observed in production: a managed 1-minute review job stalled for 20 hours
because a GitHub-webhook direct run claimed the job 2s before the Chronos
fire arrived; every subsequent occurrence was orphaned while /api/status
stayed green.

Fix: after a *claimed* direct execution completes (success or failure —
next_run_at advances at claim time either way), call
_notify_provider_jobs_changed_safe() so the active provider re-arms the
post-run next_run_at. No-op for the built-in ticker; claim-lost direct
runs still never notify (the winning scheduler owns the re-arm).
2026-07-24 13:37:04 +10:00
kyssta-exe 65d7c7fafd fix(cron): execute job immediately on action='run'
`cronjob(action='run')` (and `hermes cron run`) only set `next_run_at = now`
and returned success, relying on the scheduler ticker to actually execute the
job on its next tick. When no gateway/ticker is running — a CLI-only setup, or
the Windows case in #41037 — the job never executed: `run` reported success,
but `last_run_at` stayed null forever, no output, no delivery.

A manual `run` should actually run. `_execute_job_now` now:

- **claims the job via `claim_job_for_fire`** — the same at-most-once CAS the
  scheduler/external-provider fire path uses. This both advances `next_run_at`
  for recurring jobs and blocks a concurrently-running gateway ticker from
  double-firing the same job; if the claim is lost, the run is skipped (the
  tool reports `execution_skipped`). This closes the double-fire race that a
  bare `advance_next_run` left open (a tick whose `get_due_jobs` already
  captured the job between trigger and advance would still fire it).
- **delegates firing to `run_one_job`** — the single shared
  execute→save→deliver→mark body the ticker and external providers use — so
  failure delivery, `[SILENT]` handling, and live-adapter delivery stay
  identical across paths and can't drift. (The original salvage re-implemented
  this sequence inline and had already dropped failure delivery + `[SILENT]`.)

The tool response carries `executed`, `execution_success`, and either
`execution_error` or `execution_skipped`. The `hermes cron run` CLI message no
longer claims "It will run on the next scheduler tick" — it reports the actual
"Ran now: succeeded/failed" outcome (or the skip).

Salvaged from #41130 by @kyssta-exe (authorship preserved); reworked to reuse
`claim_job_for_fire` + `run_one_job` per review rather than re-implementing the
fire sequence inline. Adds tests for the claim-then-fire path, claim-lost skip,
failure reporting, and exception capture.

Fixes #41037

Co-authored-by: kyssta-exe <kyssta-exe@users.noreply.github.com>
2026-06-21 13:28:04 +05:30