teknium1 fcbdcdb428 fix(cron): let a skewed early fire own its armed slot
The future-instant guard in claim_job_for_fire dropped the occurrence
identity for ANY claim ahead of the stored next_run_at. A hosted/webhook
fire for the armed slot that arrives a few seconds early (the fire
scheduler's clock runs ahead of ours) was therefore treated as an
off-tick run: it ran occurrence-free, mark_job_run recomputed the same
cron slot from a now still before it, and the tick/misfire backstop then
ran the slot a second time.

Only claims at least FIRE_CLAIM_SKEW_SECONDS (60 s) ahead of the slot are
now classified off-tick, so dashboard/manual far-future fires stay
occurrence-free while a skewed early fire keeps the slot identity.
completed_occurrence honours the same window so the early run's
completion row (finished just before the slot) still proves the slot
done instead of being discarded as poison.

Review finding: claim_job_for_fire future-instant guard had no skew tolerance; an early hosted fire for the armed slot ran twice.
2026-09-15 06:07:32 -07:00
..