3671c9f188
Salvaged from PR #53395 by @izumi0uu: the fire claim's 300s TTL is routinely outlived by real cron jobs, so claim_job_for_fire alone cannot stop a manual cronjob(action='run') from double-firing a job the ticker (or another manual run) is still executing. Extract the ticker's _submit_with_guard running-set check into shared module-level helpers (try_register_running_job / release_running_job) and register manual runs through the same set — one dedupe owner, no drift. Manual runs also become visible to get_running_job_ids (the gateway shutdown drain, #60432) and mark_running_jobs_interrupted, which previously could not see them. The background dispatch path pre-checks the running set so a mid-run job reports 'already running' in the tool response immediately instead of as a delayed error completion event; the authoritative atomic check remains in _run_claimed_job on the worker. Co-authored-by: izumi0uu <izumi0uu@gmail.com>