`hermes dashboard --stop` decided its exit code by re-scanning the process table after the kill. On macOS a launchd KeepAlive job brings the backend back on a fresh PID within the grace window, so the re-scan found it and --stop exited 1 right after printing that the stop succeeded and that the job restarts itself. Judge the exit code from the kill result instead: exit 1 only when a matched pid could not be stopped.