After updater.stop() times out, HTTPXRequest.initialize() is a no-op unless the client is already closed, so start_polling reused the wedged socket and the gateway stayed alive but deaf. Rebuild the polling client after a hung drain, watch getUpdates I/O independently of get_me(), and enable TCP keepalive on the fallback transport.